Thermal

Cooler, Longer-Lived GaN Amplifiers for RF Hardware Engineers

Independent analysis by Starro. Not client work.

A small RF power amplifier package on a copper base with a faint blue glow from its chip

Objective

Where the Heat Goes in a GaN-on-SiC Amplifier

Gallium nitride amplifiers power radar, satellite links and 5G base stations. Channel temperature sets their life, and the package below the die is often chosen late, when changing it costs the most.

Where does the heat go in a flange-mounted GaN-on-SiC amplifier, and which package change buys the most life?

Findings

Flange and Attach Hold Most of the Temperature Rise

The hottest finger reaches 192 °C, a rise of 122 K. The flange alone accounts for 40 K, because it must spread heat from a 3.6 mm² die to a 60 mm² base, and about 67 % of the rise lies below the die. The center fingers run 31 K hotter than the outer ones.

A copper flange lowers the peak by 23 K, sintered silver attach by 6 K, and both together by 30 K: 5 to 30 times the Arrhenius life. Wider finger pitch gains 16 K, while thinning the SiC to 50 µm makes the device 12 K hotter.

Contribution of each layer to the 122 K peak rise, and peak temperature of each of the 20 gate fingers.

Approach

Package Model With an Exact Gate-Finger Solution

A 20 W, 20-finger GaN-on-SiC die on AuSn attach and a CuW flange over a 70 °C cold plate. A three-dimensional finite-volume package model is superposed with an exact layered Fourier-series solution for the gate fingers, and temperature changes are converted to Arrhenius life factors for activation energies of 1.0 to 2.0 eV.

Cross section through the GaN-on-SiC die, AuSn attach, CuW flange and cooling path, with a top view of the 20 gate fingers.

Validation

Independent Finite-Volume and Convergence Checks

How we checked the model:

  • The Fourier solution matches an independent finite-volume model: peak within 0.1 % for the die and 1.0 % for the flange.

  • Doubling the series from 12,000 to 24,000 terms changes the finger correction by 0.14 K.

  • Halving and doubling the die-base boundary changes it by 0.01 K.

  • Refining the finite-volume grid 3.4 times changes the peak rise by 0.25 K.

Recommendations

Choose the Flange and Attach as Early as the Die

Choose the flange and attach as early as the die: they hold most of the temperature rise. Do not thin the SiC by reflex; with a low-conductivity attach below, the thick SiC is the best spreader in the stack. Check sensitivity to material data near the junction before committing to a life estimate.

Tools used:

3D finite-volume package model; exact layered Fourier-series finger solution; Arrhenius life factors