Objective
Thermal Gradients and Phased-Array Performance
Active phased arrays dissipate heat at every element, and each transmit/receive channel drifts in phase and gain as it warms. Teams have to choose between a bigger cooling system and better calibration.
How much do thermal gradients across an air-cooled tile degrade gain, pointing and sidelobes, and which fix recovers them?
Findings
Sidelobes, Not Pointing, Limit the Array
With 40 °C inlet air the channel temperatures span 9.2 K. Warming relative to a 25 °C factory calibration costs 0.75 dB of gain, and one temperature sensor per tile removes it. The gradient barely moves the beam: at 0.5°/°C a single tile points 0.23° off, 1.8 % of its beamwidth.
In the large array the same error repeats on every tile and raises tile-periodic lobes. The peak sidelobe rises by 2.8 dB; a one-sensor correction does not change it, doubling the heat sink and airflow recovers 1.2 dB, and per-channel temperature correction recovers all but 0.02 dB.

Approach
Coupled Thermal and Array-Factor Model of an X-Band Tile
A finite-volume thermal model of an 8 × 8 X-band tile (10 GHz, half-wavelength spacing, 2 W per channel, forced-air heat sink) coupled to an array-factor model of one tile and of a 4 × 4 array of identical tiles with a 30 dB Taylor taper. Phase coefficients from 0 to 1.2°/°C and an amplitude coefficient of −0.015 dB/°C are evaluated.

Validation
Energy Balance, Closed-Form Pointing and Monte Carlo Checks
How we checked the model:
Heat into the air equals the 128 W dissipated, to 3 parts in 10¹³.
Air outlet temperature matches the energy balance: 59.915 °C.
Halving the thermal grid moves the hottest channel by 0.01 °C.
Pointing from a linear phase gradient matches the closed-form result at 0° and 45° steering.
The random-error sidelobe floor matches theory within 0.03 dB over 2,000 trials, and the ideal Taylor pattern sits 30.24 dB below peak.
Recommendations
Correct per Channel Above a 2.2° Phase Spread
Check one number against your own hardware: the phase coefficient times the temperature spread across a tile. Below 2.2°, the peak sidelobe stays within 1 dB of design. Above it, per-channel temperature correction is a calibration task that recovers nearly all of the loss, where doubling the heat sink and airflow recovers less than half.
Tools used:
3D finite-volume thermal model; array-factor pattern model; Monte Carlo check