Independent analysis by Starro. Not client work.

A tiny ring of light on a silicon chip beside a straight light guide

Objective

Coupling a Microring Filter for Clean Channels

Data centers move more traffic over light, and silicon photonic chips separate that light into channels with microring filters a few microns across. The ring's coupling decides how cleanly it picks off one channel and how tightly it must be held in temperature.

How should a silicon microring filter be coupled to keep neighboring channels out, and what does that cost in loss and thermal control?

Findings

Isolation Costs Loss and Thermal Margin

With power coupling κ² = 0.05 and 2 dB/cm loss, the ring drops its channel with 0.12 dB loss, a 313 pm bandwidth and a loaded Q of 4958, but the neighboring 100 GHz channel leaks in at −14.3 dB.

Reaching 25 dB isolation needs κ² below about 0.014. At κ² = 0.01 the leakage is −27.8 dB, but drop loss rises to 0.60 dB and the ring must stay within ±0.24 K, because its resonance moves 70 pm/K. On a 200 GHz grid, κ² = 0.03 gives −24.6 dB isolation with 0.20 dB loss and a ±0.7 K window.

Neighbor leakage, drop loss and temperature window against power coupling κ² for 2 and 5 dB/cm loss.

Approach

Effective-Index Ring Model Across Coupling Strength

A 5 µm silicon add-drop ring (450 × 220 nm strip in silica) modeled with the effective-index method, Sellmeier material dispersion and the standard ring transfer functions. Drop loss, adjacent-channel crosstalk on the ITU 100 and 200 GHz grids and thermal tolerance are mapped against coupling strength.

Add-drop microring filter between an input bus and a drop bus, with the coupling gaps that set κ².

Validation

Independent Solver and Closed-Form Checks

How we checked the model:

  • The slab effective index matches an independent finite-difference solver: 2.8482 against 2.8484.

  • The free spectral range read from the spectrum is within 1.3 % of the closed form.

  • Loaded Q matches the closed-form linewidth: 4958 against 4961.

  • The thermal shift matches the closed form: 69.56 against 69.57 pm/K.

Recommendations

Budget Thermal Control With the Filter

Single rings suit 200 GHz grids with active thermal control; 100 GHz grids favor higher-order filters. Thermal control, not lithography alone, decides whether a ring filter keeps its channel clean, so budget the heater and control loop with the filter.

Tools used:

Effective-index waveguide model with Sellmeier dispersion; ring transfer functions