Thermal
Contained Cell Failures for Battery Pack Engineers
Independent analysis by Starro. Not client work.

Objective
Stopping Propagation in a 21700 Module
Battery packs for vehicles, drones and energy storage are packed tight. The potting that spreads heat in normal use can also carry a failure from one cell to the next. Finding that in an abuse test costs a pack, a redesign and a retest.
When one 21700 cell fails in a 12-cell module, does the heat carry to its neighbors, and what barrier stops it?
Findings
Sleeves Work but Need a Protected Module Top
With potting only, the hottest neighbor wall stays above 185 °C from 20 to 86 seconds and peaks at 224 °C. With 1.5 mm aerogel sleeves, it peaks at 84 °C after about 190 seconds, as long as a duct carries the vent gas away.
The sleeves stop heat that moves through the sides of the cells, not heat from above. If about 24 % of the vent heat (roughly 9 kJ) lands on the lid, the neighbor passes 101 °C. If the lid touches the cell tops, the neighbor reaches 128 °C.

Approach
Transient 3D Conduction Model of a Potted Module
A transient 3D heat model of a potted module of 12 cylindrical 21700 cells, with a liquid cold plate below and a 2 mm aluminum lid above. One cell in the middle row fails and releases 85 kJ: 44.7 kJ into its body and 40.3 kJ in the vent gas.
We judge each design by the hottest point on any neighbor cell wall, against three measured temperatures for this cell type: self-heating starts near 101 °C, the cell vents at 116 to 127 °C, and runaway takes hold near 185 °C.

Validation
Energy Balance, Time Step and Grid Checks
How we checked the model:
Heat in equals heat stored plus heat out in every run, to better than 1 part in a million.
Halving the time step changed the peak by 0.4 °C or less.
Coarse, base and fine grids: 214, 224 and 226 °C with potting; 90, 84 and 85 °C with sleeves.
With three unfavorable inputs combined, the sleeve design reaches 110 °C.
Reference: Schöberl et al., Journal of Power Sources 648 (2025) 237240.
Recommendations
Design the Module Top as Part of the Barrier
Aerogel sleeves are the right first barrier, but they have little margin on their own. Duct the vent gas away from the module and keep the lid and busbars from bridging the cell tops. Then confirm the design in an abuse test, with the risky paths already closed.
Tools used:
Transient 3D heat model (finite volume, Python)